beautypg.com

Troubleshooting, Specifi cations / especifi caciones, Problem possible cause remedy – Essick Air RM301A User Manual

Page 4

background image

4

110522-1

Problem

Possible Cause

Remedy

Failure to
start or no air
delivery

Inadequate
air delivery
with cooler
running

Inadequate
cooling

1. No electrical power to

unit

Fuse

blown

Circuit

breaker

tripped

• Electric cord un-

plugged or damaged

2. Belt too loose or tight
3. Motor overheated

• Belt too tight

• Blower bearings dry

4. Motor locked

1. Insuffi cient air exhaust

2. Belt too loose

3. Pads plugged

1. Inadequate exhaust in

house

2. Pads not wet

Pads

plugged

• Open spots in pads

Trough

holes

clogged

• Pump not working

properly

1. Check power

Replace

fuse

Reset

breaker

• Plug in cords or

replace if damaged

2. Adjust belt tension
3. Determine cause of

overheating

• Adjust belt tension

• Oil blower bearings

4. Replace motor

1. Open windows or

doors to increase air
fl ow

2. Adjust belt tension or

replace if needed

3. Replace pads

1. Open windows or

doors to increase air
fl ow

2. Check water distribu-

tion system

Replace

pads

Repack

pads

• Clean trough and

unplug holes

• Replace or clean

pump

Troubleshooting

Motor cycles
on and off

Noisy

Excessive
humidity in
house

Musty or
unpleasant
odor

Water drain-
ing from
cooler

1. Low voltage
2. Excessive belt tension
3. Blower shaft tight or

locked

4. Bearings dry

1. Bearings dry
2. Wheel rubbing blower

housing

3. Loose parts

1. Inadequate exhaust

1. Stale or stagnate water

in cooler

2. Pads mildewed or

clogged

3. Pads not wetting

properly

Trough

holes

clogged

• Pump not working

properly

1. Float arm not adjusted

properly

2. Drain assembly leak-

ing

1. Check voltage
2. Adjust belt tension
3. Oil or replace bear-

ings

4. Oil bearings

1. Oil bearings
2. Inspect and realign

3. Tighten loose parts

1. Open doors or win-

dows

1. Drain pan and clean

pads

2. Replace pads

3. Check water distribu-

tion system

Clean

• Replace or clean

pump


1. Adjust fl oat

2. Tighten nut and drain

cap.

Problem

Possible Cause

Remedy

Model

Modelo

Volts

Voltios

Amperage

Ameraje

Speed

Velocidad

Water Capacity (gal)

Capacidad de Agua (galón)

Weight (lbs.)

Peso (libras)

Dry

Seco

Operating

Lleno

M201A

115

4.7

2

4.8

62

102

M301A / RM301A

115

7.9

2

9.2

107

184

M401A / RM401A

115

10.5

2

11.3

169

263

Specifi cations / Especifi caciones

This manual is related to the following products: