beautypg.com

Maintenance, Limited warranty, Routine maintenance – Essick Air RM301A User Manual

Page 3: Annual maintenance

background image

3

110522-1

replace if necessary. Check the ten-
sion on the belt. A 3 lb. force should
defl ect the belt 3/4 inches (see Fig.
4). Readjust belt if needed.

Clean pump. Cleaning the pump

is necessary once a year at start-up.
For your safety, turn unit off and unplug unit and pump. Remove
the pump from the mount slot. Remove the base of the pump (Fig.
5). Clean the pump and turn the impeller to ensure free operation.
Remove the pump spout and check for any blockage. After clean-
ing, reinstall the base onto the
pump. Press fi rmly to make sure
it is secure. Reattach the pump
to the mount in the cooler using
the plastic retainer to ensure that
the pump will not overturn. Do
not forget to replace the spout
and water delivery tube onto the
pump outlet.

Routine Maintenance

Drain water. It is recommended to drain the water from the

cooler at least once a week. Keeping fresh water in the pan will
help prevent scale and mineral deposits accumulation on the pads.
Always drain all of the water out of the cooler when not in use for
prolonged periods, and particularly at the end of the season.

• Unplug unit from power supply during extended periods of

non-use.

• Cover unit or store inside when not in use.

By following the operating, installation, and maintenance suggestions
as outlined, you can get many years of effi cient and satisfactory
service from your cooler. In the event additional information is
desired, your dealer will be more than glad to assist you in every
possible way.

Maintenance

WARNING:

Before doing any maintenance be sure power is

off and unit is unplugged. This is for your safety.

Annual Maintenance

Oil bearings. The blower bearings (M401A & RM401A only)

and cooler motor in this unit should be oiled with a few drops of
non-detergent 20/30 weight oil once each year. The motor does
not need oil if it has no oil lines for oiling. Motors that have no oil
lines are lifetime oiled at the factory and require no further oiling
for the life of the unit.

CAUTION:

Do not over oil. Over oiling can cause motor burn

out, due to excessive oil getting into motor winding.

Change Pads. Pads should be replaced once or twice a season,

depending upon the length of the season. At the beginning and at
mid season a clean pad is more absorbent and effi cient and will
deliver substantially more cool air.

Check belt and belt tension. This applies only to models

(R)M401A which are belt driven. Models M201A and (R)M301A
have direct drive motors. Check the belt for any cracks or wear and

Float Body

Float Rod

Washer

Nut

Garden Hose
Adapter

Fig. 3

Note: Do Not Overfi ll. Fill water to a maximum height of 2 1/2

inches (approximately 1 inch from the top of the bottom pan). If
using a garden hose, the fl oat will need to be adjusted to maintain
this water level. This can be accomplished by bending the fl oat
rod.

Impeller

Remove

Base

Fig. 5

Fig. 4

3 Lb.

3/4 Inches

Limited Warranty

This warranty is extended to the original purchaser of an evaporative cooler installed and used under normal conditions. It does not cover damages in-
curred through accident, neglect, or abuse by the owner. We do not authorize any person or representative to assume for us any other or different liability
in connection with this product.

Terms And Conditions Of The Warranty

For Two Years from date of purchase, we will replace any original component provided by Champion Cooler which fails due to any defect in material or
factory workmanship only.

Exclusions From The Warranty

We are not responsible for replacement of cooler pads. These are disposable components and should be replaced periodically. We are not responsible for
any incidental or consequential damage resulting from any malfunction.

We are not responsible for any damage received from the use of water softeners, chemicals, descale material, plastic wrap, or if a motor of a higher horse-
power than what is shown on the serial plate is used in the unit.

We are not responsible for the cost of service calls to diagnose cause of trouble, or labor charge to repair and/or replace parts.

How To Obtain Service Under This Warranty

Contact the Dealer where you purchased the evaporative cooler. If for any reason you are not satisfi ed with the response from the dealer, contact the Cus-
tomer Service Department: Champion Cooler, 5800 Murray Street, Little Rock, Arkansas 72209. 1-800-643-8341. [email protected].

This limited warranty applies to the original purchaser only.

Register your product online at www.championcooler.com/eac/onlineregistration-eac.htm