beautypg.com

Cooler installation, Operation, Wiring diagrams – Essick Air RM301A User Manual

Page 2: Installing casters, Manual control units, Remote control units, Exhaust air, Manual control remote control, Connecting water

background image

2

110522-1

Cooler Installation

Installing Casters

Note: The installation kit

includes (2) swivel cast-
ers with brake, (2) swivel
casters without brake, (16)
tinnerman nuts and (16)
1/4-20 x 1/2 screws.

• Place the unit on its side.

Place the tinnerman nuts on
the caster bracket on the bot-
tom pan as shown in fi gure
1.

• Attach the casters to the

brackets with the screws provided.

Operation

Manual Control Units

Pump setting. The rotary switch has 6 settings. The “Pump”

setting will operate the pump without the blower. For best results
turn the switch to “Pump” for a few minutes to wet the pads before
operating the fan.

High and low cool settings. The “High Cool” and “Low Cool” set-

tings operate both the pump and the blower. Turn the unit to “Low
Cool” when possible. This lower speed allows the air to stay longer
in the wet pads and therefore increases it’s cooling effi ciency.

High and low vent settings. The “High Vent” and “Low Vent”

settings operate the blower without the pump. This is useful on
cool nights or at times when just a fan is desired.

Remote Control Units

These units may be controlled using the 3 buttons on the front panel
of the cooler or with the remote control.

• PUMP button. Pressing this button toggles the pump on and off.

When the LED is lit, the pump is running. For best results turn
on the pump for a few minutes to wet the pads before operating
the fan. The pump must be on while operating the fan for cooling.
You may also want the pump turned off at times when just a fan is
desired.

• FAN button. Pressing this button will cycle the fan through High

Speed / Low Speed / Off. The LED’s on the front of the control
indicate wether the fan is on high speed, low speed or off (no LED’s
lit). Note: There will be a 2 second delay between a button press
and the operation of the fan.

• ON/OFF button. Pressing this button while the pump or fan is on

will turn everything off. Pressing it again while in the off state will
return the fan and pump to their previous operating settings. When
fi rst plugging in the cooler or after power has been interrupted,
pressing the On/Off button will start the cooler in the default state
which is with the pump on and the fan on high.

• Remote Control. To operate the cooler with the remote you must

be within 20 feet and in sight of the cooler. Aim the remote at the
front panel. The buttons on the remote control have the same func-
tions as the buttons on the front panel of the cooler. The remote
uses two AAA alkaline batteries which are included. A holder for
mounting on a wall is also included with the unit.

Connecting Water

Install drain assembly. Place the

nipple through the hole in the pan,
with the rubber washer between the
pan and the head of the drain nipple
(Fig. 2). Thread nut onto nipple and
draw up tight against bottom of pan.
Thread the drain cap to the nipple and
tighten water tight.

Install fl oat valve. Refer to fi gure 3. Install the valve in the pro-

vided hole in the corner post ((R)M301A, (R)M401A) or louvered
side (M201A) using the provided washer and nut. Install the
included garden hose adapter to the fl oat as shown if attaching a
garden hose to the unit. A 1/4 inch water line may also be used to
supply a continuous amount of water to the unit.

Fill pan with water. You may fi ll the pan manually for up to 3

hours of cooling. For automatic fi lling you may attach a garden
hose to the garden hose adapter or a 1/4 inch water line to the fl oat
valve.

Fig. 1

Bottom Pan

Nipple

Rubber Washer

Nut

Drain Cap

Fig. 2

Wiring Diagrams

White-Com.

Black-Hi

Black

Blower

Motor

Pump

Motor

Red-Lo

White-Com.

Green-Ground

Green

Switch

A

B

1

2

3

4

Ribbed-Com.

Plain

Green

Exhaust Air

If the unit is used in an enclosed area, open windows or doors to
ensure adequate exhaust. Without an outlet to exhaust the air,
humidity will build up in the enclosed space and the unit will not
cool adequately.

Manual Control

Remote Control

Hi
Low

Gnd
Com.

Black
Red
Green

White

Ground
Wire

Blower Motor

Pump

Motor

Blower Panel

Control

Ground

Screw

Junction Box

(RM301A)

This manual is related to the following products: