11 warning menu, 1 fan failure – EverFocus EDR-1640 User Manual
Page 50
3.11 WARNING MENU
49
3.11.1 FAN FAILURE
The EDR provides warning functions allowing signalling upon operation failure. Define the
alarm reactions in the WARNING menu.
Both fans provide failure detection. Define the alarm reactions upon fan failure in this menu
item:
(1)BUZZER: By selection “ENABLE”, the buzzer is activated upon fan failure.
(2)ALARM OUTPUT: Output relay activation.
1 – Output relay 1 (for EDR410/810, only one output relay is available)
NONE – no relay reaction upon alarm.
(3) ALARM DURATION: PERMANENT - This value cannot be changed, alarm is
automatically switched off after problem has been solved
(fan replacement).
(4) NETWORK ALARM:
YES: Network alarm activated (for settings refer to NETWORK menu)
Network alarm reception requires optional PowerCon software.
NO: No network alarm transmission
(5) EMAIL:
YES: Alarm email transmission (for settings refer to NETWORK menu).
NO: No email alarm transmission.
WARNING SETUP MENU
FAN FAULT
BUZZER
ENABLE
HDD TEMP.
ALARM OUTPUT
1
NO HDD
ALARM DURATION PERMANENT
HDD FULL
NETWORK ALARM NO
EMAIL
NO