beautypg.com

Pow8131, 13 assistant fence function (fig 13), 14 laser function (fig. 12) – Powerplus POW8131 TELESCOPIC MITRE SAW 1500W 210MM EN User Manual

Page 9: 15 cleaning and maintenance, 16 technical data

background image

POW8131

EN

Copyright © 2010 VARO

P a g e

| 9

www.varo.com

§ Firmly press on the saw shaft lock (17) and slowly rotate the flange bolt in clockwise

direction. The saw shaft lock engages after no more than one rotation.

§ Now, using a little more force, slacken the flange bolt in clockwise direction.
§ Turn the flange bolt until it is completely removed.
§ Take the blade (5) off the inner flange and pull out downwards.
§ Mount the new saw blade in reverse order and fasten.
§ Important! The cutting bevel of the teeth, i.e. the direction of rotation of the saw blade, has

to conform with the direction of the arrow marked on the housing.

§ Clean the saw blade flanges thoroughly before mounting the saw blade.
§ Reattach the movable blade guard (6) in reverse order.
§ Before using the saw again, check that the safety devices are in good working order.
§ Important: Every time that you change the saw blade, check to see that it spins freely in

the groove of the turntable in both perpendicular and 45° angle settings.

13 ASSISTANT FENCE FUNCTION (FIG 13)

§ When angle of blade is 90°, please fit on part (A)
§ When angle of blade is 45°, please loose screw (a) to remove part (A)

14 LASER FUNCTION (FIG. 12)

You can switch the laser ON and OFF with the switch (a).
The laser (35) directs a beam onto the work-piece.
Extremely precise cuts can be made using the laser function.

15 CLEANING AND MAINTENANCE

15.1

Maintenance

Keep the machine's air vents unclogged and clean at all times.
Remove dust and dirt regularly from the machine. Cleaning is best done with compressed air
or a rag.
Re-lubricate all moving parts in regular intervals.
Never use caustic agents to clean plastic parts.

15.2

Service department

§ Damaged switches must be replaced by our after-sales service department.
§ If the connecting cable (or mains plug) is damaged, it must be replaced by a particular

connecting cable which is available from our service department. Replacement of the
connecting cable must only be carried out by our service department (see last page) or by
a qualified person (qualified electrician).

16 TECHNICAL DATA

Power

230 V~ 50 Hz

Output

1500W S6

Idle speed n

0

5000 min

-1

Carbide-tipped saw blade

210 x 30 x2.6mm

Number of teeth

24

Tilting range

-45° / 0° / +60°

Mitre cuts

0° to 45° to the left

Sawing width at 90°

305 x 58 mm

Sawing width at 45°

210 x 58 mm

Sawing width at 2 x 45°
(double mitre cuts)

305 x 32 mm
210 x 32 mm