MAINTENANCE
Incomplete cleaning could cause function failures and a degradation of
the fan form.
Remove any remaining paint by pouring it into another container.
Disassemble the spray gun making sure to remove the needle before disassembling
the nozzle to avoid damage to the housing of the nozzle closure.
Clean all the paint passages and the nozzle. Clean the other components using a
brush soaked in solvent.
Reassemble the spray gun and spray a small quantity of solvent to eliminate all the
residues in the paint passages.
Warning: Never use metal or other objects that could damage the holes in
the nozzle and cap. never immerse the spray gun completely in solvent.
never use components or parts that are not manufacturer originals.
7
STORING
When not using spray gun, turn the fluid adjustment knob counter-clockwise to open
which will reduce spring tension on needle fluid tip.
Spray gun MUST BE well cleaned and lightly lubricated.
8
TECHNICAL DATA
POWAIR0105
POWAIR0106
Air inlet
¼”
¼”
Type of feed
Gravity
Suction
Standard diameter of nozzle
1.5mm
1.5mm
Recommended air pressure
3.0-4.0bar (44-58psi)
3.0-4.0bar(44-58psi)
Max. pressure of air
5bar / 72.5psi
5bar / 72.5psi
Paint capacity
400cc
750cc
Avg. air consumption
119-201l/min (4.2-7.1cfm)
119-201l/min (4.2-7.1cfm)
Pattern width
160-210mm (6.3-
8.3”)
140-180mm (5.5-
7.1”)