129
• When View Window values are changed, the graph display is cleared and the
newly set axes only are displayed.
• View Window setting may cause irregular scale spacing.
• Setting maximum and minimum values that create too wide of a View Window
range can result in a graph made up of disconnected lines (because portions of
the graph run off the screen), or in graphs that are inaccurate.
• The point of deflection sometimes exceeds the capabilities of the display with
graphs that change drastically as they approach the point of deflection.
• Setting maximum and minimum values that create to narrow of a View Window
range can result in an error (Ma ERROR).
k
k
k
k
k
Initializing and Standardizing the View Window
uuuuu
To initialize the View Window
a. Press
!3
(V-Window)
1
(INIT) to initialize the View Window to the following
settings.
Xmin
= –6.3
Ymin
= –3.1
Xmax
= 6.3
Ymax
= 3.1
Xscale = 1
Yscale = 1
b. Press
!
3
(V-Window)
2
(TRIG) to initialize the View Window to the follow-
ing settings.
Deg Mode
Xmin
= –540
Ymin
= –1.6
Xmax
= 540
Ymax
=
1.6
Xscale =
90
Yscale =
0.5
Rad Mode
Xmin
= –9.4247779
Xmax
= 9.42477796
Xscale = 1.57079632
Gra Mode
Xmin
= –600
Xmax
= 600
Xscale = 100
• The settings for Y min, Y max, Y pitch, T/
θ
min, T/
θ
max, and T/
θ
pitch remain
unchanged when you press
2
(TRIG).
View Window (V-Window) Settings