Administrator’s Guide and Operating Instructions

21

??Go to Preset- The option will be available while the focus camera is

a PTZ camera. Check the box and enter the desired preset location.
The corresponding PTZ camera will automatically go to the preset
location while the alarm action is triggered. For more details of the
preset location settings, please refer to Chapter 7 PTZ Control
Functions.

?? Pre-record – Pre-record time to define how long (in seconds) before

the Alarm Action is triggered the Focus Camera shall be intensively
recorded (Note 2). Use the Up/Down arrow buttons to adjust the
value (0-10 seconds).

?? Post-record - Post-record time to define how long after the Alarm

Action is triggered the Focus Camera shall be recorded at Alarm
Recording Rate. Please refer to Camera Setup for Alarm Recording
Rate of Camera. Use the Up/Down arrow buttons to adjust the
value (0 seconds-60minutes).

?? Enable – Check to enable the Alarm Output when the Alarm Action

is triggered.

?? Alarm Out – To define which Alarm Output will be triggered when

the Alarm Action is triggered. NC and NO signals are available,
please refer to Alarm Out Setup. Click on the Down arrow button
to select one of the Alarm Outputs (AO 1-8).


?? Output – Alarm Out output state when the Alarm Action is triggered.

For NC signal, it’s always open, for NO signal close. The Normal
State above shows whether the selected Alarm Out is NC signal or
NO signal.

?? Buzzer On – To activate the internal buzzer or not when the Alarm

Action is triggered.

?? Log – Log to event log list or not. Please refer to Log Display for

the details.

?? Show Message – To display the alarm message or not when the

Alarm Action is triggered.

?? Any Key To Stop – When the Alarm Action is triggered, the internal

buzzer and Alarm Out relay may be activated. If you want to stop
those actions by pressing any key or moving/clicking the mouse,
please check this item.