beautypg.com

Installation, Positioning, Location – Electrolux 925033685 User Manual

Page 16: Electrical connection

background image

Installation

WARNING!

Read the "Safety Information" carefully for your safety and correct operation of the ap-

pliance before installing the appliance.

Positioning

Install this appliance at a location where the ambient temperature corresponds to the

climate class indicated on the rating plate of the appliance:

Climate class

Ambient temperature

SN

+10°C to + 32°C

N

+16°C to + 32°C

ST

+16°C to + 38°C

T

+16°C to + 43°C

Location

The appliance should be installed well away from

sources of heat such as radiators, boilers, direct

sunlight etc. Ensure that air can circulate freely

around the back of the cabinet. To ensure best

performance, if the appliance is positioned below

an overhanging wall unit, the minimum distance

between the top of the cabinet and the wall unit

must be at least 100 mm . Ideally, however, the

appliance should not be positioned below over-

hanging wall units. Accurate levelling is ensured

by one or more adjustable feet at the base of the

cabinet.
WARNING!

It must be possible to disconnect the appliance

from the mains power supply; the plug must therefore be easily accessible after installation.

Electrical Connection

CAUTION!

Any electrical work required to install this appliance should be carried out by a qualified

electrician or competent person.

WARNING!

This appliance must be earthed.

The manufacturer declines any liability should these safety measures not be observed.

A

B

mm

mm

min

10

0

20

16

Installation