beautypg.com

7 unit weight calibration – Excell Precision Counting Scale User Manual

Page 15

background image

EXCELL PRECISION CO., LTD

.

Counting ZSME200000003

13

2-7 UNIT WEIGHT CALIBRATION

Two methods of unit weight calibration are available depending on the scale

configuration they are either:-

1. Auto Calibration

if weight is over 10% of the last sampling value, the scale

will automatically re-calculate the unit weight.

Example:

Say the current unit weight is 2.5g. If the next batch of product of the same
type has a slightly different unit weight say 2.8g, then because the difference
between the to unit weights is greater than 10% the scale will average the two
values and set a new unit weight of 2.65g. If the difference in unit weights are
less than 10% then the unit weight is not re-calculated.

2. Manual Calibration

Press SMPL key to determine the unit weight.

The Auto Unit Weight calibration is setting is a factory set option. If it is set to off

then the auto unit weight calculation is disabled.