Start the engine, Storing the engine, Overload protection 2 x 230 v sockets – Parkside PSE 2800 A1 User Manual
Page 19: Cleaning
19
GB/MT
Safety instructions / Before use / Operation
… / Cleaning, maintenance, storage, transport and ordering replacement parts
Make sure you have adequate ventilation.
Ensure that the spark cable is securely in the
spark plug.
Unplug any electric device connected to the
generator.
Start the engine
ATTEnTIon! When starting with the express
start
13
you can injure your hand with the sudden
kick back.
Wear protective gloves when starting.
Open the petrol tap
14
by turning the tap down-
wards.
Put the on / off switch
11
to the on position.
Turn the choke lever
12
to I I (in the left
position).
Start the engine with the express start
13
by
sharply pulling the handle. If the engine has not
started pull the handle again.
Push the choke lever
12
back once the engine
has started (in the right position).
To load the generator
Connect the device to the 230 V∼ socket
3
.
ATTEnTIon! This socket can be loaded con-
tinuously (S1) with 2600 W and short term (S2) for
a maximum of 2 minutes with 2800 W.
note: Some electric devices (sabre saws, drills etc.)
can use more electricity when doing heavy duty tasks.
Storing the engine
Before putting away, let the generator run with-
out load so that the device can „cool down“.
Turn the on / off switch
11
to the „OFF“ position.
Close the petrol tap
14
.
overload protection
2 x 230 v sockets
WArnInG! This generator is fitted
with an overload protector.
This cuts off the sockets
3
. By activating the over-
load switch
6
the sockets
3
can be used again.
ATTEnTIon! If this happens reduce the
amount of electrical output which you are
extracting from the generator or remove
defective devices which are attached.
ATTEnTIon! faulty overload switches
should only be replaced with identically
constructed overload switches with the
same performance data. Please use our
customer service department.
cleaning, maintenance, stor-
age, transport and ordering
replacement parts
Before cleaning and maintenance work, turn off the
engine and pull the spark plug connector
28
out of
the spark plug
27
.
ATTEnTIon! Turn the device off imme-
diately and contact your Service Station:
- With unusual vibrations or noises.
-
If the engine seems overloaded or has backfired.
cleaning
Keep the safeguards, air vents (fig. B / Pos. B1)
and the engine housing as dust and dirt free as
possible. Wipe the device with a clean cloth or
blow it with compressed air with low pressure.
We recommend that you clean the device after
every use.
Regularly clean the device with a damp cloth
and a little soft soap. Do not use any cleaning
products or solvents which could attack the plas-
tic part of the device. Ensure that no water can
penetrate the housing.