Safety instructions / before use / operation, Before use installation, Electrical safety – Parkside PSE 2800 A1 User Manual
Page 18: Environmental protection, Earthing, Operation

18 GB/MT
Safety instructions / Before use / Operation
11. Emission levels are represented in the technical
data under the stated values for sound power
level (L
WA
) and sound pressure level (L
pA
) and
are not compulsory definite working levels. Be-
cause there is a connection between emission
levels and immission levels, this can not reliably
used to determine the potentially necessary ad-
ditional precautions. Influencing factors on the
workforce‘s current immission level includes the
properties of the work area, other noise sources,
air borne sound, etc. such as e.g. the number
of machines and other neighbouring processes
and intervals, to which the user is exposed. Also
the admissible immission levels can vary from
country to country. However, this information
gives the user of the machine the opportunity to
have a better estimation of the risks and dangers.
Occasionally acoustic measurements should be
take after installation in order to determine the
sound pressure level.
ATTEnTIon: only use unleaded normal
petrol as fuel.
Important! Switch off
the engine before refueling.
Important! Hot parts.
Keep your distance.
Please read all safety in-
formation and instructions.
Failure to observe the safety information and in-
structions can result in electric shock, fire and / or
serious injury.
keep all safety advice and instructions in
a safe place for future reference.
Before use
Installation
You will need two open ended spanners
for install this device (spanner size 12).
Install the stand
17
, wheels
15
and the push
bar
19
as shown in figures F–I.
Install all parts before pouring in the fuel and
oil to avoid the fluids leaking.
To install the wheels first push the wheel axle
16
through the brackets on the underside of the
generator and install the wheels
15
as shown
in figure G.
Ensure that when installing the push bar
19
the
slanting side (fig. I / Pos. I1) is slanting outwards.
Electrical safety
Electrical cables and attached devices must be
defect free.
Never connect the generator to the mains
(power point).
Keep the cables as short as possible.
Environmental protection
Dispense of polluted maintenance and operating
materials in a suitable collection point.
Earthing
Earthing is needed to disperse static discharge.
Connect a cable from one side of the earthing
connector
4
of the generator (fig. C / Pos. 4)
and from the other side to an external ground.
operation
ATTEnTIon! When being used for the first
time, motor oil (15 W-40, approx. 0.6 l) and petrol
(unleaded normal petrol) must be put in.
Check the fuel level and the oil, and if necessary
top them up.
… / Cleaning, maintenance, storage, transport and ordering replacement parts