3. Set the desired disc onto the
mounting flange (
B
12). label on
the disc should always face the
device.
4. Set the clamping nut (
B
13) on
the mounting spindlel (
B
14)
again. The flat side of the clam-
ping nut must face the attach-
ment tool.
5. Press the spindle stop button
(
7) and pull the clamping
nut (
B
13) tight again using the
chuck key (
9).
Operation
Caution! Risk of injury!
- Always remove the mains plug
before working on the tool.
- Only use grinding discs and
accessories recommended by the
manufacturer. Using other attach-
ment tools and other accessories
can represent a risk of injury for
you.
- Only use grinding tools which
bear information about the
manufacturer, type of binding,
dimension and permitted number
of revolutions.
- Only use grinding discs where
the printed rotational speed is at
least as high as what has been
specified on the name plate of
the device.
- Do not use any broken, cracked,
or otherwise damaged grinding
discs.
- Never operate the device wit-
hout protective equipment.
Keep your hands away from
the disc when the device is in
operation. Risk of injury.
Information on replace-
ment:
• Never operate the device without
protective equipment.
• Ensure that the rotation speed
stated on the grinding disc (
10) ) is the same or higher than
the nominal rotation speed of the
device.
• Ensure that the grinding disc
dimensions match those of the
device.
• Only use flawless grinding discs
(ringing test: when you strike the
grinding disc with a plastic ham-
mer, it results in a clear sound).
• Never re-drill a locating hole
which is too small to make it lar-
ger.
• Never use separate bushings or
adapters in order to make grin-
ding discs with a hole that is too
large fit the device.
• Do not use any saw blades.
• To clamp the grinding tools
only use the clamping flange
provided. The pads between
the clamping flange and the
grinding tools must be made of
elastic materials e.g., rubber,
soft cardboard etc.
• Always reassemble the device
completely after replacing the
grinding disc.
Switch the device off and remove
the mains plug. Allow the device to
cool down.
Wear protective gloves when chan-
ging the grinding discs in order to
avoid cutting damages.