11. Possible causes of failure

Problem

Cause

Solution

The compressor
does not start.

1. No supply voltage.

2. Insuffi cient supply voltage.

3. Outside temperature is too low.

4. Motor is overheated.

1. Check the supply voltage, the pow-

er plug and the socket-outlet.

2. Make sure that the extension cable

is not too long. Use an extension
cable with large enough wires.

3. Never operate with an outside tem-

perature of below +5° C.

4. Allow the motor to cool down. If

necessary, remedy the cause of the
overheating.

The compressor
starts but there is no
pressure.

1. The non-return valve leaks.

2. The seals are damaged.

3. The drain plug for condensation

water (9) leaks.

1. Have a service center replace the

non-return valve.

2. Check the seals and have any da-

maged seals replaced by a service
center.

3. Tighten the screw by hand. Check

the seal on the screw and replace if
necessary.

The compressor
starts, pressure is
shown on the pres-
sure gauge, but the
tools do not start.

1. The hose connections have a leak.

2. A quick-lock coupling (4, 20) has

a leak.

3. Insuffi cient pressure set on the pres-

sure regulator (3).

1. Check the compressed air hose and

tools and replace if necessary.

2. Check the quick-lock coupling and

replace if necessary.

3. Increase the set pressure with the

pressure regulator.