Information about warranty and service processing, Warranty terms, Scope of warranty – Parkside PDSS 310 A1 User Manual
Page 14
14 GB
… / Environmental instructions and disposal information / Declaration of Conformity
Troubleshooting / Information about warranty and service processing
Information about warranty
and service processing
Creative Marketing Consulting GmbH
warranty
Dear customer, the warranty for this device is 3
years from the date of purchase. In the event of
product defects you have legal rights against the
retailer of this product. Your legal rights are not li-
mited in any way by our warranty detailed below.
Warranty terms
The warranty period begins on the date of purchase.
Please keep the original sales receipt in a safe lo-
cation. This document is required as your proof of
purchase.
Should this device show any fault in materials or
manufacture within three years from the date of
purchase, we will repair or replace it - at our choice -
free of charge to you. Warranty services require
the defective device and the proof of purchase (sales
receipt) to be presented within the three-year period
along with a brief written description of the defect
and when it occurred.
If the defect is covered by our warranty, we will re-
turn the repaired device or replacement thereof. A
repair or exchange of the device does not extend a
new warranty period.
Scope of warranty
The device has been manufactured to strict quality
guidelines and meticulously examined before delivery.
The warranty applies to faults in material or manuf-
acture. This warranty does not apply to product
Faults
Possible causes
Action
Impact driver not
working
Trigger not pulled
Pull trigger
No compressed air supply If applicable, drain condensation from tube (water
bag)
Straighten kinks in the hose
Connect compressed
2
air
Leak in compressed air
system
Remedy leak
Compressor defective
Verify the compressor is supplying compressed air. If
necessary, have compressor repaired by a qualified
professional
Defect inside the air tool
Have air tool repaired by a qualified professional
Not properly tight-
ening screw
Air pressure too low
Increase air pressure.
ATTENTION! Never exceed the maximum ap-
proved operating pressure of the air tool!
Not loosening
screw
Torque is too low
Turn torque control
3
to a higher setting
Rusted screw
Apply rust remover to screw
73786_par_Druckluft-Schlagschrauber PDSS 310 A1_content_LB4.indd 14
31.05.12 12:21