Typical applications, Regreleasenum – Linx Technologies TRM-915-DTS User Manual
Page 17

– –
– –
28
29
Release Number - NV Address = 0x78
This register indicates the firmware release number for the module. Figure
38 translates the release numbers to firmware versions. Figure 39 shows
examples of the command.
Release Number to Version Number
Release Number
Module Type
Version Number
0
DTS
1.1.0
1
EUR
1.2.6
2
DTS
1.2.6
3
EUR
1.3.1 (current)
4
DTS
1.3.0 (current)
5
DTS-FCC
1.3.0 (current)
8
DTS-FCC
1.3.0 (current)
18
DTSB
1.3.0 (current)
Figure 38: Release Number Command and Response
Figure 39: Release Number Command and Response
Release Number
Read Command
Read Response
Header
Size
Escape
Address
ACK
Address
Value
0xFF
0x02
0xFE
ADDR
0x06
ADDR
REL#
Typical Applications
Figure 40 shows a circuit using the DTS Series transceiver.
The transceiver UART is connected to a microcontroller UART for
communication of configuration data and data to be sent over the air.
There is no need for buffering or other circuitry between the transceiver and
microcontroller provided that both are operating on the same voltage.
RESET
GND
1
NC
2
NC
3
CMD
4
RXD
5
TXD
6
CTS
7
NC
8
NC
9
C2D
10
11
GND
12
ANT
13
GND
14
GND
15
GND
16
GND
17
GND
18
VCC
19
GND
VCC
ANTENNA
GND
GND
GND
GND
GND
GND
GND
RXD
TXD
GPIO
GPIO
µ
Figure 40: DTS Series Transceiver Basic Application Circuit