Main G-Force Troubleshooting Guide
9
April 5, 2006
Document #300116 Rev. A
Complaint: RPM seems too high
Probable Cause: Sensor installed parallel to the floor. When installed parallel to
floor, the sensor will often pick up the magnet twice as it passes.
Complaint: Part of console won’t light up
Probable Cause: If any small portion of the board will not light up, replace
console assy.
Complaint: All of console won’t light up
If customer is trying to operate console without pedaling
Probable Cause: Confirm batteries are installed properly per diagram in battery
case. Note that they must be Double A (AA) Nickel-Metal-
Hydride (Ni-MH) rechargeable batteries which are about 1.2
Volts when fully charged
Correct RPM Sensor
mounting – Sensor is
parallel to the frame
Incorrect RPM Sensor
Mounting – Sensor is
parallel to the floor.