Torque procedure – Jordan Valve Mark 58 Series – Globe Style Back Pressure Regulator User Manual
Page 3

-3-
remain with the stem. To remove plug see preceding
section.
Inspect parts for wear and replace as required. It is
5.
recommended that the o-ring be replaced.
Clean all parts and the o-ring seating surfaces in the
6.
body and on the cage. Lightly lubricate these sur-
faces and the o-ring. Do not lubricate bore of cage
where the plug operates.
Check to see that the ball (13) is below the tapped
7.
hole for the adjusting screw and reinstall the adjust-
ing screw to just contact the ball.
Install the cage o-ring and screw the cage into the
8.
body until it bottoms out and tighten. Readjust ad-
justing screw.
Torque Procedure
Install all bolts hand-tight.
1.
Torque the bolts in order of the bolt pattern to a
2.
value equal to 1/4 of the recommended torque
valve.
Retorque each bolt to recommend value using the
3.
same bolt pattern as shown.
When ordering spare parts, first make a note of the fol-
lowing information on the valve’s nameplate:
— Serial Number
— Model and Size
— Body Material and End Connections
— Range
5
3
1
6
4
2
5
3
1
6 4
2
7
8
6 bolts (or multiples)
8 bolts (or multiples)
- Mark 51 Series – Self-Operated Back Pressure Regulator (4 pages)
- Mark 51 Series – Self-Operated Back Pressure Regulator (4 pages)
- Mark 62 Series - Internally Piloted Regulator (5 pages)
- Mark 52 Series – Internally Piloted Regulator (5 pages)
- Mark 64 Series – Differential Regulator (2 pages)
- Mark 56 Series – Air Loaded Back Pressure Regulator (5 pages)
- Mark 57 Series – Externally Piloted Regulator (4 pages)
- Mark 508 Series – Tank Blanketing Valve (4 pages)
- Mark 508 Series – Tank Blanketing Valve (3 pages)
- Mark 608DS – Double Seated High Capacity Tank Blanketing Regulator (17 pages)
- Mark 5108 Series Back Pressure Regulator (4 pages)
- Mark 6127 Series Pressure Reducing Valves (5 pages)
- Mark 6127 Series Pressure Reducing Valves (4 pages)
- Mark 61 Series - Sliding Gate Pressure Regulator (5 pages)
- Mark 61 Series - Sliding Gate Pressure Regulator (4 pages)
- Mark 61 Series - Sliding Gate Pressure Regulator (4 pages)
- Mark 66 Series – Air Loaded Pressure Regulator (5 pages)
- Mark 67 Series – Piloted Sliding Gate Regulator (5 pages)
- Mark 608 Series – Low-Pressure Gas/Tank Blanketing Regulator (4 pages)
- Mark 608DS – Double Seated High Capacity Tank Blanketing Regulator (18 pages)
- Mark 608IS – Tank Blanketing/Low Pressure Gas Regulator (5 pages)
- Mark 608DS – Double Seated High Capacity Tank Blanketing Regulator (2 pages)
- Mark 627 Series - Gas Service Regulator (4 pages)
- Mark 630 Series - Gas Service/High Pressure Regulator (5 pages)
- Mark 686 Series – Air Loaded Globe Regulator (4 pages)
- Mark 687 Series - Piloted Regulator with Class VI Shutoff (4 pages)
- Mark 688 Series - Piloted Soft Seat Regulator (11 pages)
- Mark 695 Series - Piloted Tank Blanketing Regulator (9 pages)
- Mark 68HP Series – High Pressure Regulator (2 pages)
- Mark 80 Series – Self Operated Temperature Regulator (7 pages)
- Mark 80 Series – Self Operated Temperature Regulator (2 pages)
- Mark 80 Series – Self Operated Temperature Regulator (5 pages)
- Mark 82 Series – Internal Piloted Temperature Regulator (5 pages)
- Mark 85 Series - Controlled Failure Temperature Regulator (5 pages)
- Mark 86 Series - Ambient Temperature Regulator (2 pages)
- Mark 87 Series - Piloted Temperature Regulator (6 pages)
- Mark 89MX Series- Three-Way Temperature Regulator (4 pages)
- Mark CFR Series Pressure Reducing Supply Реле (3 pages)
- Mark 25 Series – Tempilot Temperature (4 pages)
- Mark 4160 Series Pressure Controllers (11 pages)
- 657M Series Diaphragm Actuator (7 pages)
- 667M Series Diaphragm Actuator (8 pages)
- 1051M Series Rotary Actuator (12 pages)