Command List
COMMAND
Bytes
C1,C2,C3,C4
PARAMETER
Bytes
P1,P2,..
DESCRIPTION
All feedback is in the same format. In this way the
response will echo the command if the command is
valid.
NOTES
MPWR
Main Power
00
Off (Standby)
01
On
QS
Query Status
AUFB
auto-feedback
00
OFF - automatic response on device status change or
button press actions will not be broadcast(only the
responses to explicit commands)
01
Automatic response will always be sent.
Recommended to be sent
on power up
QS
query, return AUFB status
MSRC
Main Source
System power on defaults
to last used source
00
Blu-ray
01
SAT / VBL
02
Game
03
Media Player
04
DVR
05
TV
06
CD
07
BAL2
08
USB
09
7.1 Bypass
QS
Query Status
MVOL
Main Volume
MVOL can be used to set
the volume, bump it
up/down. The unit will
respond with a MVOL and
the current volume. MVOL
commands have built in
RAMP TIME that cannot
be defeated
UP
Up 1 step (0.5dB)
DN
Down 1 step (0.5dB)
xxxx
0200 - 1120 in 0.1dB units, plus 1000 (-80.0..12.0dB res
0.5dB). Fourth digit must be 0 or 5 (xxx0 or xxx5).
QS
Query Status
QVOL
Quick Volume Command (Main Zone)
Same as MVOL but
without any RAMP TIME.
UP
Up 1 step (0.5dB)
The unit will go to the
volume without any ramp
DN
Down 1 step (0.5dB)