FF Length

Adjusts the length of media moved (in inches) if a manual form-feed, remote
form-feed, or an end of transmission (EOT) is detected, up to 99 inches. The
default setting is 5 inches.

Top -of-Form (TOF) Adjust

Advances the media for a set distance after a top of form is detected. This is
to compensate for manufacturer’s different placements of the TOF mark from
the perforation.

End of Transmission (EOT) Cut

If enabled, a media cut will be performed after a remote end of transmission is
detected, and at the end of a form-feed.

Nib Save

This option can prolong head life if plot borders and vertical lines are used
often, since they are usually plotted in the same horizontal position on the
page. By moving the location of the vertical lines between different plots,
wear is spread out to the different areas of the head. NIB SAVE can enable
the plot to be shifted on different plots horizontally between the sides of the
page or can lock down the positioning to a specific location. When enabled,
the plot shifting will occur on a remote form-feed or end of transmission.

Hysteresis Adjust

Adjusts the contrast (darkness) of any dither pattern excluding solid black.