NOTE: An item is selectable when an arrow is displayed, and changeable
when arrow is flashing. You can only move to another menu item if there is
one or more equal (=) signs elsewhere on the screen. Holding down the up or
down arrow key while a menu item is selected, will scroll through the item
options until a menu limit has been reached or the arrow key released. To run
a test plot: Press ON/OFFLINE, press menu select until you reach the test
plot screen, scroll down using down arrow key, press manual advance to
select item, press up arrow key to change from “NO” to “YES”. The plot will
begin after about 3 seconds and will automatically change the menu item from
“YES” back to “NO” once the plot is finished. The CUT MEDIA button will
terminate a plot during plotting and will continue to kill jobs until a remote
form-feed or end of transmission is received.

4.5

CONTROL PANEL FUNCTIONS AND SETTINGS

Control panel settings are saved as presets for either USER M1 or USER
M2. Presets are initially set to defaults for all menu functions.

Changes to function settings are stored upon pressing MANUAL ADVANCE.
Changes are retained even while the main power is off.
To restore the default settings for both USER modes, turn the power switch
on while pressing down the MENU SELECT button.

User Mode

Allows the user to select between two user defined settings (eg. User Mode 1
for film; User Mode 2 for paper). To access functions in either user mode:
Select ON/OFFLINE, press MENU button until user mode is displayed,
press MANUAL ADVANCE to select, arrow will flash, press up arrow,
deselect item by pressing MANUAL ADVANCE again.