5 installation procedure – Yaskawa AC Drive V1000-Series Option SI-M3/V CompoNet User Manual
Page 20

5 Installation Procedure
20
YASKAWA ELECTRIC TOBP C730600 54A V1000 Option CompoNet Installation Manual
4.
On IP20/Open-Chassis models, connect the drive-side of the ground wire to the
drive ground terminal.
Note: The four different ground wires packaged with the option connect the option to different drive
models. Select the proper ground wire depending on drive size.
Figure 7
Figure 7 Connect the Ground Wire on an IP20/Open-Chassis Drive
5.
For IP20/Open-Chassis models, go to Step
6.
For IP20/NEMA Type 1 Enclosure models CIMR-V
A
F, loosen the screw
on the front of the NEMA Type 1 terminal cover and remove it from the drive. Refer
for details
Refer to
for drive models CIMR-V
BA0006F to BA0018F, 2A0008F to
2A0069F, and 4A0001F to 4A0038F, which require removing the plastic terminal
cover prior to removing NEMA Type 1 terminal cover.
Note: Installing the option on an IP20/NEMA Type 1 enclosure drive voids NEMA Type 1 protection
while maintaining IP20 conformity.
Figure 8
Figure 8 Remove the NEMA Type 1 Terminal Cover
Ground terminal
Ground wire
Ground wire
Drive-side
connector
Screw size:
M3.5 to M6
Option unit
connector
Screw size: M3