beautypg.com

New u1 monitors – Yaskawa G5 Output Voltage PID User Manual

Page 6

background image

Date: 07/01/04, Rev: 04-07

Page 6 of 6

TM.G5SW.022

New U1 Monitors


U1-50

Aux PID Vref

A - - -

Aux PID Vref

U1-50= 0.00%


Displays the percentage of the PID voltage set point input on terminal 16.

U1-51

Aux PID Vfb

A - - -

Aux PID Vfb

U1-51= 0.00%


Displays the percentage of PID voltage feedback input on terminal 14.

U1-52

Aux PID Output

A - - -

Aux PID Output

U1-52= 0.00%


Displays the percentage of PID output that is summed with the voltage set point.

Range:

0 to 100.00%

Modbus Address: 0x00d1

Range:

0 to 100.00 %

Modbus Address: 0x00d2

Range:

0 to 100.00%

Modbus Address: 0x00d0