VS-616/676 Series Option Instruction Manual: Isolated Analog Monitor Card AO-12B2

Note: Refer to “OUTPUT SIGNAL LEVEL SETTING” for 100% output signal level in output content.

Table 8: Programming Settings With VS-616H3

Terminal

Program

Constant No.

Set

Value

Output Contents

Output

Accuracy

TB1-1

Channel 1

bn-15

1

Frequency reference:

Max. frequency/100%

1.0%

2

Output frequency:

Max. frequency/100%

3.0%

3

Output current

Rated current/100%

1.5%

4

Output voltage reference:

input voltage/100%

1.5%

5

DC voltage (V

PN

)

400v/100% (200V class)

TB1-2

Channel 2

bn-17

6

Output Power

(+ indication):

Rated power (kW) 100%

10%

17

Speed feedback (PG,G):

Max. frequency/100%

18

Compensated

frequency (PG,TG):

Max. frequency/100%

19

Voltage feedback (AVR):

Input voltage/100%

20

Compensated voltage (AVR):

Input voltage/100%

21

Momentary reduced value:

Max. frequency/100%