6 using the copy function – Yaskawa JVOP-181 USB Copy Unit User Manual
Page 17

6 Using the Copy Function
YASKAWA ELECTRIC
TOBP C730600 25D JVOP-181 Technical Manual
17
rdEr
Error reading data
rEAd
Reading parameter settings (flashing)
vAEr
Voltage class and/or unit capacity does not
match
vFyE
Parameter settings in the unit and those
saved to the option are not the same
vrFy
Comparing parameter settings (flashing)
<1> Parameters can only be copied to a unit when the power
supply specifications, capacity, control mode, and software
version match.
<2> Press and hold the Copy button for one second. The option
will copy parameter settings previously saved to the option to
the unit.
<3> Replace the option.
<4> Connect the option to a unit with the proper parameter
settings and press and hold the Read button for one second.
The option will then save the settings from the unit.
<5> Press and hold the Read button for one second. The option
will save the settings from the unit.
Display
Description