beautypg.com

SMA SB 2000HF-US User Manual

Page 18

background image

Information on the Display

SMA America, LLC

18

HF_STP_US-BUS095110

User Manual

Position

Description

A

PV array event number
Shows events that have occurred on the PV array.

B

Warning icon for power reduction.
The temperature in the inverter is too high. The inverter reduces power output in order
to cool down. If the inverter fan is dirty, clean it (see section 5.1 ”Cleaning the Fan”
(page 19)).
If the inverter displays the icon even after the fan has been cleaned, ensure
proper ventilation.

C

Inverter event number.
It displays events that have occurred on the inverter.

D

Grid event number.
This displays events that have taken place on the power distribution grid.

E

Event display line of text.
The text field displays additional information if any events have occurred on the PV
array or on the power distribution grid. Tapping on the lid leads you to further
information on the event.

Display messages
The inverter installation manual provides detailed information regarding event numbers,
various error and malfunction messages.
Measurement accuracy
The inverter does not have a calibrated meter. The values on the display unit may differ
from the actual values. You may not use the values as the basis for any billing purposes.

This manual is related to the following products: