4 measurement channels and messages, 1 measurement channels – SMA SB 2800i User Manual
Page 36
Technical Documentation
Operating Instructions
34
SMA Regelsysteme GmbH
SB2800i-11:FE0504
6.4 Measurement Channels and Messages
If your Sunny Boy 2800i has been equipped with a communication interface, numerous
measurement channels and messages can be acquired. These can help improve the performance
as well as eliminate failures of your plant.
BFR
: System control
SRR
: Current control
6.4.1 Measurement Channels
E-Total
Total power fed to the grid accumulated from the day of installation
Fac
Grid frequency
Störung/Failure
Display of failure type in „ Failure“ state
h-Total
Total sum of operating hours in feeding operation
Iac-Ist
Current fed to the grid
Ipv
Current from PV-panels
Netz-Ein/Power ON
Total number of connections to the grid
Pac
Present output power
Riso
Insulation resistance of PV plant before the connection to the grid
Seriennummer/Serial
number
Serial number of the Sunny Boy
Status/Mode
Display of current operating state
Uac/Vac
Grid voltage
Upv-Ist/Vpv DC
PV input voltage
Upv-Soll /
Vconst-Setpoint
PV setpoint voltage
Zac