beautypg.com

SMA MATRIX Quick Reference Guide User Manual

SMA Equipment

background image

Matrix_SEN103510 | 98-0040110 | Version 1.0

Plant Monitoring

SUNNY MATRIX

Quick Reference Guide - Creating a Slide Show

EN

Explanation of Display Areas:

A display area is made up of modules on the Sunny Matrix. A module consists of 4 positions. The

Sunny Matrix can display a character at each of these positions. You can compile display areas

with different lengths of these modules and positions. The Sunny Matrix modules are always

numbered from left to right, from top to bottom. The numbering is required for compiling the

display areas.

Display areas are already predefined before shipping the Sunny Matrix and noted for you on the

configuration sheet included in the delivery.

Normally every line with modules is predefined as a display area. The following example shows

the normally predefined display areas of a Sunny Matrix with 2 lines, with 4 modules, each.

Defining the display area (example):

The following display areas are to be defined:

• A display area is to be saved as

[7]

and made up of the following modules: module 1 with

positions 1 to 4, module 2 with positions 1 and 2.

• A display area is to be saved as

[8]

and made up of the following modules: module 2 with

positions 3 to 4, module 3 with positions 1 to 4 module 4 with positions 1 to 4.

1

Select Display > Configuration.

2

In the “Definable displays“ area select [7].

3

Defining the display area:

3.1

Activate the first selection field and select the following settings in the drop-down lists:

“Module“ 1, “Start“ 1, “Length“ 4.

3.2

Activate another selection field and select the following settings in the drop-down lists:

“Module“ 2, “Start“ 1, “Length“ 2.

4

Select [Save].

5

In the “Definable displays“ area select [8].

6

Defining the display area:

6.1

Activate the first selection field and select the following settings in the drop-down lists:

“Module“ 2, “Start“ 3, “Length“ 2.

6.2

Activate another selection field and select the following settings in the drop-down lists:

“Module“ 3, “Start“ 1, “Length“ 4.

6.3

Activate another selection field and select the following settings in the drop-down lists:

“Module“ 4, “Start“ 1, “Length“ 4.

7

Select [Save].

SMA Solar Technology AG

Sonnenallee 1

34266 Niestetal, Germany

www.SMA.de

SMA Serviceline

Inverters:

+49 561 9522 1499

Communication: +49 561 9522 2499

Fax:

+49 561 9522 4699

E-Mail:

[email protected]

If you have technical problems concerning our products, contact the SMA Serviceline. We

require the following information in order to provide you with the necessary assistance:
• Type of inverter

• Type of communication interface between Sunny WebBox and the inverters

• Sunny Matrix firmware version

• Sunny Matrix serial number of the system board

• Sunny Matrix serial number

CoNTACT

DEFINING THE DISPLAY AREAS

A

Numbering of modules and positions:

Module

Display Area [1]

Display Area [7]

Display Area [2]

Display Area [8]

Position