6 Removing the SMA String-Monitor from the Pole
Danger to life from electric shock due to live voltage
High voltages are present in the live components of the DC sub-distribution. Touching live
components results in death or serious injury due to electric shock.
• Disconnect the inverter on the DC side (see the inverter manual).
• Disconnect the DC sub-distribution (see the DC sub-distribution manual).
• Disconnect all DC sub-distributions that are connected in parallel in the DC connection area
(see the manual of the respective DC sub-distribution).
Risk of injury when lifting the DC sub-distribution, or if it is dropped
There is risk of injury if the DC sub-distribution is lifted incorrectly or dropped while being
transported or when attaching it to or removing it from the wall mounting bracket. Weight of the
DC sub-distribution without installed accessories: 35 kg.
• Two persons are required for mounting and disassembling the DC sub-distribution.
• Carefully lift and transport the DC sub-distribution.
Procedure:
1. A clean and scratch-proof surface for the SMA String-Monitor must be provided.
2. Decommission the SMA String-Monitor (see the SMA String Monitor manual).
3. Loosen the screws of the fixing brackets on both steel wires. Make sure that the SMA String-
Monitor does not fall down.
4. Remove the screws of the fixing brackets on both steel wires and take the SMA String-Monitor
off the pole. Position the SMA String-Monitor with the front on the prepared surface.
5. Fold back the ends of the steel wires and remove the fixing brackets.
6. Slowly pull out the steel wires from the polyester brackets.
7. Remove the screws from the C profile rails and then remove the C profile rails.