SMA String-Monitors Pole Mounting Set User Manual
Page 16
Procedure:
1. Position the SMA String-Monitor with the front on a clean and scratch-proof support surface.
Make sure that the enclosure of the SMA String-Monitor is not damaged.
2. Attach the C profile rails to the upper and lower
wall mounting brackets of the SMA String-
Monitor using one screw, two washers and one
nut for each rail.
3. Lead a steel wire through the polyester bracket
of each of the C profile rails until the polyester
bracket is in the middle of the steel wire.
4. Perform the following steps for both steel wires:
• Pull the ends of the steel wire through the
fixing bracket until the steel wire is adjusted
to the dimensions of the pole.
• Fold the ends of the steel wire back and shorten if required. At least 30 mm on both ends
must protrude. The steel wire is thus firmly positioned in the fixing bracket.
• Remove both fixing brackets from the screw
connection and place them in readiness for
pole mounting.
• Push the SMA String-Monitor with the upper
and lower polyester bracket against the
pole and connect the ends of the fixing
brackets with the screw, the washer and the
nut. Tighten the screws until the SMA String-
Monitor is firmly attached to the pole.
5 Mounting the SMA String-Monitor on the Pole
SMA Solar Technology AG
Installation Manual
SSMUMast-IA-xx-10
16
ENGLISH