4  Electrical Connection

SMA Solar Technology AG

16

MFR-NR-IA-en-21

Installation Manual

4. Insert the multifunction relay in the inverter. Lead the

left-hand key on the multifunction relay into the hole
in the plastic retainer for the display assembly.

5. Lead the ribbon cable upwards behind the display

assembly.

6. Fasten the multifunction relay using the washer and

the cylindrical screw (torque: 1.5 Nm). Use an
Allen key (AF 3).

7. Flip the display assembly down.

8. Tighten the screw of the display assembly.