6 connecting the cables to the 485 data module – SMA 485 Data Module Type B User Manual

Page 17

background image

SMA Solar Technology AG

5  Electrical Connection

Installation Manual

485BRD-10-IA-en-12

17

5.6 Connecting the Cables to the 485 Data Module

Figure 4: Overview of the connection area

Connect each cable to the 485 data module according to the following procedure.

1. Plug one spring-cage connector into each of the

sockets on the 485 data module.

2. If one cable is to be connected, attach the terminator:

• Push the levers of the terminals 2 and 7 of one spring-cage connector upwards.
• Bend the ends of the terminator downwards

and plug the terminator into the open terminals.

• Push the levers back down.

3. Push the levers of the terminals 2, 5 and 7 of one

spring-cage connector upwards.