beautypg.com

Enerco MHVFB10LPI User Manual

Page 10

background image

10

Installation instructions and Owner’s Manual

Figure 16

CAUTION: Do not try to adjust heating level by using

equipment shutoff valve.

WARNING: When running heater, set control knob at

“LO” or “HI” locked positions. Poor combustion and

higher levels of carbon monoxide may result if heater

is operated with control knob positioned between

locked positions.

IMPORTANT: Release downward pressure while turning

control knob. Control knob must be locked at the

desired position.

TO TURN OFF GAS TO APPLIANCE

SHUTTING OFF HEATER:

1. Turn control knob clockwise to the OFF position.
2. Turn off equipment shutoff valve.

SHUTTING OFF BURNER ONLY (PILOT STAYS LIT)

1. Turn control knob clockwise to the PILOT/IGN

position.

INSPECTING BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 17 show a correct pilot flame pattern. Figure 22

shows an incorrect pilot flame pattern. The incorrect

pilot flame pattern is not touching thermocouple. This

will cause the thermocouple to cool. When the thermo-

couple cools, the heater will shut down. If pilot flame

pattern is incorrect, as shown in Figure 22:

Turn heater off (see To Turn OFF Gas to Appli-

ance, page 10 for non-thermostat models).

See Troubleshooting, pages 12 and 13.

Figure 22

CLEANING AND MAINTENANCE

WARNING: Turn off heater and let cool before

servicing.

CAUTION: You must keep control areas, burner and

circulation air passageways of heater clean. Inspect

these areas of heater before use. Have the heater

inspected yearly by a qualified service person. Heater

may need more frequent cleaning due to excess lent

from carpeting, bedding material, pet hair, etc.

Control Knob

Figure 17