beautypg.com

I – 3 diagnostics – HEIDENHAIN IOB 49 User Manual

Page 16

background image

16

I Operating Instructions

I – 3 Diagnostics

CSS

CSS DIAGNOSTICS shows the status of the communication via the
CAN bus and the state of the DAC output to provide monitoring of the
interfaces for operation with constant surface speed. The state of the
switching inputs and outputs is also shown.

The CAN STATUS field shows the state of the bus communication
between the position display unit and the IOB 49.

The status information has the following meaning:

The DAC OUTPUT field shows the current value of the transmitted
voltage. The value is between 0 and 4095, which corresponds to a
voltage of 0 to 10 V at X102-11. The corresponding CSS icon will be
displayed if the spindle speed is at the upper or lower limit (

or

).

The CSS INPUT/OUTPUT field shows the state of the switching
inputs and relay outputs.

Information

Meaning

NOT PRESENT

No communication with hardware

NOR

Communication – normal operation

CAL

Communication – Hardware in calibration
mode

Wen

Watchdog active

Wds

Watchdog inactive

Wto

Watchdog time-out

Tx

Data is transmitted to hardware

Rx

Data is received by hardware