Initial Installation

24" (610mm)

Maximum

Horizontal

24" (610mm)

Minimum

Vertical

Inside

Finished

Collar

Wall

Thimble

Horizontal

Vent

Termination

Exterior

Wall Surface

Insulation

Interior Wall

Surface

If installed on a

carpeted surface

a hearth is required

Interior

Wall Surface

2.5"

(64mm)

Inside

Finished

Collar

Horizontal

Vent Section

Exterior

Wall Surface

Horizontal

Vent

Termination

Wall

Thimble

Insulation

If installed on a

carpeted surface

a hearth is required

NOTES:
(1)
The horizontal run of vent pipe must

be level and should have a 1⁄4” rise

for every one foot of run towards

the termination. Never allow the

vent to run downward. This could cause

high temperature and may present the

possibility of a fire.

(2) The location of the horizontal vent

termination on the exterior wall must not

be easily blocked or obstructed. Refer

to I

NITIAL

I

NSTALLATION

- V

ENT

T

ERMINATION

R

ESTRICTIONS

.

(3) When installing a vent pipe in a chase

the minimum clearance to combustibles

is 2” (51 mm).

NOTE: Vent pipe must not be longer

than 18” (457 mm) maximum when

installing straight through exterior wall.

Maintain manufacturer’s clearances to

combustibles with venting.
Vent may extend between 6” (152 mm)

and 18” (457 mm) maximum straight

out.

When installing this unit in a corner the

maximum distance after 45˚ elbow is 9”

(228 mm).
If between 9” (229 mm) and 24” (610

mm), a 14” (356 mm) snorkel must be

used.

Figure 26: Straight Through Wall Installation.

Figure 27: Up Then Through Wall Installation.