the cap assembly. It is important that the

vent pipe extend into the vent cap a sufficient

distance with a minimum of 11⁄4” (3.2 cm)

overlap. Secure the connection between the

vent cap pipe and the vent cap by attaching

the two sheet metal straps extending from

the vent cap assembly into the outer wall of

the vent pipe. Use the two sheet metal screws

provided to connect the straps to the vent

pipe. Bend any remaining portion of the sheet

metal straps back towards the vent cap, so the

decorative wall thimble will conceal it (see left

image in Figure 23).

STEP 7. Slide the decorative wall thimble up to the wall

surface and attach with the screws provided.

Apply decorative brass or chrome trim if

desired (see right image in Figure 23).

NOTES:
(1)
The four wood screws provided should be replaced

with the appropriate fasteners for stucco, brick,

concrete, or other types of siding.

(2) For buildings with vinyl siding, a vinyl siding

standoff, should be installed between the vent cap

and the exterior wall (see Figure 24). Attach the

vinyl siding standoff to the horizontal termination.

The vinyl siding standoff prevents excessive heat

from possibly melting the vinyl siding material.

Note that the horizontal vent termination bolts onto

the flat portion of the vinyl siding standoff (shaded

area in Figure 24), so that an air space will exist

between the wall and the vent termination.

Initial Installation

QUALIFIED INSTALLERS ONLY

Figure 24: Installing Vent Cap with Vinyl Siding

Stand-Off.

Figure 25: Installing Horizontal Vent Termination.

STEP 3. With the pipe attached to the stove in the correct location, mark the wall for a 10” (25.4 cm) x

10” (25.4 cm) square hole (refer to Figure 22). The center of the square hole should match the

center line of the horizontal pipe. Cut and frame the 10” (25.4 cm) x 10” (25.4 cm) hole in the

exterior wall where the vent will be terminated. Refer to Figure 15. If the wall being penetrated

is constructed of non-combustible material i.e. masonry or concrete, a 7 inches (17.8 cm) hole

is acceptable.

STEP 4. Position the horizontal vent termination in the center of the 10” (25.4 cm) x 10” (25.4 cm)

hole, and attach to the exterior wall with the four screws provided. Before attaching the vent

termination to the exterior wall, run a bead of non-hardening mastic around the edges, so as to

make a seal between the termination and the wall. The arrow on the vent termination should be

pointing up, insure that the proper clearances to combustible materials are maintained.

STEP 5. Before connecting the horizontal run of the vent pipe to the vent termination, slide the black

decorative wall thimble cover over the vent pipe.

STEP 6. Slide the appliance and vent assembly towards the wall, carefully inserting the vent pipe into