Initial Installation

QUALIFIED INSTALLERS ONLY

P

LANNING

Y

OUR

I

NSTALLATION

:

When planning your installation, it will be necessary to select the proper length of vent pipe for your

particular requirements. It is important to note when passing through a wall, the maximum allowable

wall thickness is 10 inches (25.4 cm), 11⁄2 inches (3.8 cm) clearance to combustibles must be maintained.

Select the amount of vertical rise desired for “vertical-to-horizontal” type installations. To determine

the length of vent pipe required for vertical installations, measure the distance from the appliance flue

outlet to the ceiling, the ceiling thickness, the vertical rise through the attic or second story, and allow

for sufficient vent height above the roofline. For two story applications, a fire stop is required at each

floor level. If an offset is needed in the attic, additional pipe and elbows will be required. To connect the

venting system to the appliance flue outlet, a twist-lock adapter is built into the appliance at the factory.

Refer to I

NITIAL

I

NSTALLATION

- V

ENT

C

ONFIGURATION

AND

R

ESTRICTOR

S

ETTINGS

for venting parameters.

Your total vent pipe length must be within the shaded area of Figure 36. If a 90° elbow is used in the

horizontal plane, 36” (91.4 cm) must be subtracted from the allowable horizontal run.

There are two (2) basic types of Direct Vent System installations. The two (2) types of installations are

shown below.

Vertical

Termination

Storm Collar

Flashing

Round Support

Box/Wall Thimble

Ceiling Firestop

Pipelength

Pipelength

Cathedral Ceiling

Support Box

Pipelength

Round Support

Box/Wall Thimble

Pipelength

Horizontal

Termination

90° Elbow

Figure 13: Common Horizontal Installation.

Figure 14: Common Vertical Installation.