Auxiliary connector
Figure 3-23. Auxiliary connector
4
1
2
3
5
6
7
8
9
10
11
1.
+5VL
2.
0VL
3.
AN0
4.
AN1
5.
Spare
6.
On-air n.c.
7.
Private Data Camera - Base Station
8.
Ground
9.
Private Data Base Station - Camera
10. Ground
11. Shield
Private data input signals: 0 <0.8 Volt; 1 >2.4 Volt
max. level: +/-12 Volt
input impedance: >100 kOhm
baud rate: 2400 bits/s nom; 4800 bits/s max.
Private data output signals: C-MOS levels 5V
output impedance: <1 kOhm.
Analogue outputs (AN0 and AN1) output level: 0 - 5 Volt
output impedance: 100 Ohm
Fischer 11-pole female; panel view
Panel part number (X109): 3922 040 02512
See also other documents in the category Grass Valley Equipment:
- LDK 5302 (24 pages)
- SFP Optical Converters (18 pages)
- 2000GEN (22 pages)
- 2011RDA (28 pages)
- 2010RDA-16 (28 pages)
- 2000NET v3.2.2 (72 pages)
- 2000NET v3.1 (68 pages)
- 2020DAC D-To-A (30 pages)
- 2000NET v4.0.0 (92 pages)
- 2020ADC A-To-D (32 pages)
- 2030RDA (36 pages)
- 2031RDA-SM (38 pages)
- 2041EDA (20 pages)
- 2040RDA (24 pages)
- 2041RDA (24 pages)
- 2042EDA (26 pages)
- 2090MDC (30 pages)
- 2040RDA-FR (52 pages)
- LDK 4021 (22 pages)
- 3DX-3901 (38 pages)
- LDK 4420 (82 pages)
- LDK 5307 (40 pages)
- Maestro Master Control Installation v.1.5.1 (455 pages)
- Maestro Master Control Installation v.1.5.1 (428 pages)
- 7600REF Installation (16 pages)
- 7600REF (84 pages)
- 8900FSS (18 pages)
- 8900GEN-SM (50 pages)
- 8900NET v.4.3.0 (108 pages)
- Safety Summary (17 pages)
- 8900NET v.4.0.0 (94 pages)
- 8906 (34 pages)
- 8911 (16 pages)
- 8900NET v.3.2.2 (78 pages)
- 8914 (18 pages)
- 8912RDA-D (20 pages)
- 8916 (26 pages)
- 8910ADA-SR (58 pages)
- 8920ADC v.2.0 (28 pages)
- 8920ADC v.2.0.1A (40 pages)
- 8920DAC (28 pages)
- 8920DMX (30 pages)
- 8920ADT (36 pages)
- 8920MUX (50 pages)
- 8921ADT (58 pages)