beautypg.com

13 auxiliary connector – Grass Valley LDK 500 User Manual

Page 39

background image

Cabling and connectors | Triax adapter connectors

3-14

3.3.13

Auxiliary connector

Figure 3-23. Auxiliary connector

4

1

2

3

5

6

7

8

9

10

11

1.

+5VL

2.

0VL

3.

AN0

4.

AN1

5.

Spare

6.

On-air n.c.

7.

Private Data Camera - Base Station

8.

Ground

9.

Private Data Base Station - Camera

10. Ground

11. Shield

Private data input signals: 0 <0.8 Volt; 1 >2.4 Volt
max. level: +/-12 Volt
input impedance: >100 kOhm
baud rate: 2400 bits/s nom; 4800 bits/s max.

Private data output signals: C-MOS levels 5V
output impedance: <1 kOhm.

Analogue outputs (AN0 and AN1) output level: 0 - 5 Volt
output impedance: 100 Ohm

Fischer 11-pole female; panel view

Panel part number (X109): 3922 040 02512