Grass Valley Kayenne K-Frame Installation Planning Guide Dec 03 2014 User Manual
Page 50

50
KAYENNE K-FRAME — Installation Planning Guide
Appendix 6 — Specifications
Table 3. Network Connections
Type of connection
10/100/1000 Base T
Protocol
TCP(UDP)/IP, Auto speed detection. Auto crossover cable configuration.
Cable and connectors
CAT5 UTP, RJ45 connectors;
Max. Cable Length
100m / 300ft
Table 4. PCU Interconnects
Control Panel - PCU Connections
Cable and connectors
Custom 7 Pin D style
Number Required
1 for each Control Panel Stripe, Local Aux Stripe, and Satellite Panel
Max. Interconnect Cable Length
15 m / 50 ft. (7.5 m / 25 ft. cable length also available)
Cable Weight
15 m / 50 ft.
1.3 kg (2.9 lbs)
7.5 m / 25 ft.
0.7 kg (1.6 lbs.)
Touch Screen Menu Panel - PCU Connection
Cable and connectors
Custom 17 Pin D style
Number Required
1 for each Menu Panel (2 maximum)
Max. Interconnect Cable Length
15m / 50ft (7.5m / 25ft cable length also available)
Cable Weight
15 m / 50 ft.
1.6 kg (3.7 lbs)
7.5 m / 25 ft.
0.9 kg (2.0 lbs.)
Table 5. Power
Panel Control Unit (required for Control Panel and Touch Screen Menu Panel Operation)
Line voltage
100V-240V AC +/-10% autorange, power factor corrected. Automatic line-
voltage sensing for 120V and 240V sources.
Line frequency
50/60Hz +/- 5%
Power consumption
max. 500W
Leakage current
< 2.5 mA