Appendix A — Specifications
Table 4. Network Connections
Type of connection
10/100/1000 Base T
Protocol
TCP(UDP)/IP, Auto speed detection. Auto crossover cable configuration.
Cable and connectors
CAT5 UTP, RJ45 connectors;
Max. Cable Length
100m / 300ft
Note
The K-Frame Video Processor has an internal Ethernet switch with six available external ports. One connection is
required for each Control Panel and one is required for each Menu PC. An external Ethernet switch is required to
connect more than six devices.
Table 5. Power
K-Frame Video Processor Power Supply
Line voltage
100V-240V AC +/-10% autorange, power factor corrected. Automatic line-
voltage sensing for 120V and 240V sources.
Line frequency
50/60Hz +/- 5%
Power consumption
6-RU K-Frame, max. 900W
13-RU K-Frame, max. 1400W
Leakage current
< 2.5 mA
Interconnect DC cable length
864 mm
34 in.
Table 6. Numbers of MEs, Inputs, and Outputs
Frame
M/Es
Inputs
Outputs
GPI Inputs
GPI/Tally
Outputs
Smart I/O Modules
(MatchDef/SetDef)
Compact 6-RU
1 to 5
32 to 64 plus up
to 16 MatchDef
16 to 32 dual plus 4 to
16 SetDef
8 per input
board
32 per input
board
Each Smart I/O module pro-
vides 4 inputs and 4 outputs
with up/down/cross conver-
sion capability
Standard 13-RU
1 to 9
32 to 160 plus up
to 32 MatchDef
16 to 64 dual plus up
to 32 SetDef
Board Count
Compact 6 RU
Up to 2
M/E boards
Up to 2 input
boards (32 inputs
per input board)
Up to 2 output boards
(16 dual outputs per
output board)
Up to 4 modules
Standard 13 RU
Up to 4
M/E boards
Up to 5 input
boards (32 inputs
per input board)
Up to 4 output boards
(16 dual outputs per
output board)
Up to 8 modules