Grass Valley Fibre Channel Switch User Manual
Page 11

29 January 2007
Fibre Channel Switch Installation Manual
11
Port and switch configuration
4. If you are configuring a switch with 16 or fewer ports, skip ahead to step 8.
5. If you are configuring a 20 port switch, in configuration mode, type the following
command at the prompt to view the configuration of port 16 (a 10 Gb port) on the
switch.
SANbox (admin-config) #> set config port 16
6. Modify the settings as needed. The following example shows the required settings.
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list press
'q' or 'Q' and the ENTER key to do so.
Configuring Port Number: 16
------------------------
AdminState (1=Online, 2=Offline, 3=Diagnostics, 4=Down) [Online]
LinkSpeed (10=10Gb/s) [10Gb/s]
PortType (G / F) [G]
SymPortName (string, max=32 chars) [10G-16]
DeviceScanEnable (True / False) [True]
ForceOfflineRSCN (True / False) [False]
AutoPerfTuning (True / False) [True]
MSEnable (True / False) [True]
IOStreamGuard
(Enable / Disable / Auto)
[Disabled]
Finished configuring attributes.
This configuration must be saved (see config save command) and
activated (see config activate command) before it can take effect.
To discard this configuration use the config cancel command.
7. If you are configuring a 20 port switch, repeat step 4 and step 6 for port 17, 18, and
19.
8. In configuration mode, type the following command at the prompt to configure
global switch settings:
SANbox (admin-config) #> set config switch
9. Modify the settings as needed. The following example shows the required settings.
NOTE: Each QLogic 5202 SANbox Switch must have a unique DomainID for the
local fabric. You should specify these values individually for each switch and not
allow the switches to select their own DomainID values. Setting DomainIDLock to
True prevents the switch from changing the DomainID when a new switch is added to
fabric.
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.