Chapter 3
Configuring Your System
28
Digital News Production
Setting Up Your Media Server
You need to configure your Media Server to work with IngestStation. Follow
the instructions below for your type of server.
M-Series iVDR
If you are using an M-Series iVDR as your media server with IngestStation, you
need to configure it as follows:
• Set up record channels to use Advanced Media Protocol (AMP).
• Configure channels to use LTC input (IngestStation only supports LTC
input).
See your M-Series iVDR documentation for instructions.
Profile Media Server
You configure the Profile Server differently for IngestStation depending on
they type of communication you’re using for the server—DCOM or RS-422.
DCOM
If you are using DCOM, see your Profile documentation and set up the server
as follows:
• Set up record channels using the Configuration Manager.
• Configure channels to use LTC input (IngestStation only supports LTC
input).
• When you connect, it is imperative that you don’t launch any of the Profile
interfaces; you can’t have any channels open in either the VdrPanel or the
AMP Application.
RS-422
If you are using RS-422, see your Profile documentation and set up the server
as follows:
• Set up record channels using the Configuration Manager.
• Configure channels to use LTC input (IngestStation only supports LTC
input).