8945EDA and 8945EDA-D Instruction Manual

13

Power Up

A red FAULT LED indicates an error situation and, when noted with the other indi-
cator LEDs, can indicate a specific problem area.

Table 2

describes signal output

and LED indications for the various input/reference combinations.

Table 3

provides the possible input and output conditions that result from different

input signals and conditions.

Table 2. Indicator LEDs and Conditions Indicated

LED

Indication

Condition

FAULT (red)

Off Normal

operation

On continuously

Module has detected internal fault

COMM (yellow)

Off

No activity on frame communication bus

Long flash

Location Command received by the module from a remote control system

Short flash

Activity present on the frame communication bus

CONFIG (yellow)

Off

Module is in normal operating mode

On continuously

Module is initializing, changing operating modes or updating firmware

Long flash

Location command received by the module from a remote control system

PWR (green)

Off

No power to module or module’s DC/DC converter failed

On continuously

Normal operation, module is powered

PRES COAX IN

Off

Indicates no signal present on the coax

On continuously

Indicates signal present on the coax

BYPASS

Off

No bypass of the equalizer

On continuously

Bypass of the equalizer

Table 3. Input and Output Conditions

Input Condition

Output Condition

Serial Digital Component (SDI)

Serial Digital Component (SDI)

HD Digital Component (SDI)

HD Digital Component (SDI)

Other carrier

Other carrier

No input

Passing