Configuration
provides a complete summary of the 8920ADC processing func-
tions and a comparison of the functionality available with each control type
along with the ranges and default values for each parameter.
Table 6. Summary of 8920ADC Configuration Functions
Function
Type
Default
Range/Choices
Resolution
Web Page/
Function Name
Rotary Switch
Bank/Setting
Newton
Control
Panel
Operational modes
Default
Default
L/R Swap
L/R Invert
L Invert
R Invert
R Mono (R to L/R)
L Mono (L to L/R)
L plus R to L/R
L minus R to L/R
L plus R, L minus R
(L plus R) Inv to L/R
AES Silence
1K@ -20 dBFS
Audio Control and Status/
Operational Modes pulldown
Refer to
for a description of each
setting
Function Rotary
Switch SW1.
Refer to
for
switch settings.
Op Mode
Controls type
Numeric
Numeric or Sliders
Audio Control and Status/
Controls Type pulldown
N/A
Controls
Left Channel Level
0 dB
± 6 dB
Audio Control and Status/
Left Channel Level (dB)
Refer to
Lt Level
Right Channel Level
0 dB
± 6 dB
Audio Control and Status/
Right Channel Level (dB)
Rt Level
Monitor Audio Outputs
Disabled
Enabled or Disabled
User Settings/
Monitor Audio Outputs
pulldown
N/A
Monitor