Power up, Operation indicator leds – Grass Valley 8920ADC v.2.0.1A User Manual

Page 11

background image

8920ADC Instruction Manual

11

Power Up

Power Up

The front LED indicators and configuration switches are illustrated in

Figure 4

. Upon power-up, the green PWR LED should light and the yellow

CONF LED should illuminate for the duration of module initialization.

Operation Indicator LEDs

With factory default configuration and valid input and reference signals
connected, the green PWR LED and the green LOCK LED should be on.

Figure 4. Operation Indicator LEDs

A red FAULT LED indicates an error situation and, with the other LEDs,
can indicate the operational conditions presented in

Table 2

. The table

describes signal output and LED indications for various input/reference
combinations and user settings.

Table 2. Indicator LEDs and Conditions Indicated

LED

Indication

Condition

FAULT

(red)

Off

Normal operation.

On continuously

Module has detected an internal fault.

Flashing

Reference input is faulty or not present.

COMM

(yellow)

Off

No activity on frame communication bus.

Long flash

Location Command received by the module from a remote control system.

Short flash

Activity present on the frame communication bus.

CONF

(yellow)

Off

Module is in normal operating mode.

On continuously

Module is initializing, changing operating modes or updating firmware. Simulta-
neous CONF and FAULT LEDs on indicate FPGA load error.

Flashing

Indicates rate of change of paddle-controlled analog setting.

PWR

(green)

Off

No power to module or module’s DC/DC converter failed.

On continuously

Normal operation, module is powered.

Left In
Clip (red)

Left In > -20dBFS (green)

Right In > -20dBFS (green)

Right In
Clip (red)

FAULT (red)
COMM (yellow)
CONF (yellow)
PWR (green)
REM OVER (yellow)
LOCK (green)