29

Service

Service

The 8900 Analog Video DA modules make extensive use of surface-mount
technology and programmed parts to achieve compact size and adherence
to demanding technical specifications. Circuit modules should not be ser-
viced in the field unless directed otherwise by Customer Service.

If your module is not operating correctly, proceed as follows:

Check frame and module power LEDs.

Verify power at the voltage testpoints (see

Figure 15

) and check fuses if

no voltage is detected.

Check for presence and quality of input signals.

Verify that source equipment is operating correctly.

Check cable connections.

Refer to

Figure 7 on page 16

for the location of PWR LED and

Table 4 on

page 16

for proper LED indications.

If the module is still not operating correctly, replace it with a known good
spare and return the faulty module to a designated Grass Valley repair
depot. Call your Grass Valley representative for depot location.

Refer to the

Contacting Grass Valley

at the front of this document for the

Grass Valley Customer Service Information number.

Figure 15. 8900 DA Fuse and Voltage Testpoint Locations