Configuration, Remote configuration and monitoring, Tion and monitoring system (see – Grass Valley 8900FSS User Manual
Page 11

8900FSS Instruction Manual
5
Configuration
Configuration
The configuration of the 8900FSS establishes the operation parameters
shown in
. The submodule configuration can be changed from
factory defaults using the configuration switches on the host module.
These switches are:
■
Function Switch – a function selection rotary switch (submodule func-
tions are usually addressed by the second bank of selections on this
switch).
■
Toggle Switch – a momentary toggle switch that actuates the selection
when switched either up or down.
Refer to the instruction manual for the host module for configuration
instructions.
Remote Configuration and Monitoring
The 8900FSS is designed to operate in 8900TX, TF or TFN frame versions
that support GUI-based configuration and monitoring. A PROM upgrade
on the host module may be required to activate frame bus communication
if the module is moved from a non-networking frame to a networking
frame.
Table 2. Frame Sync Configuration
Function
Switch
Toggle
Switch Up
Toggle
Switch Down
Function
Description
0
Video
Reference
†
†
Default setting.
Lock Source
Selecting Video forces delay mode even if a reference signal is
present.
1
currently not used
2
+
–
Horizontal Phase
Provides synchronizer phase adjustment in clock increments.
3
+
–
Vertical Phase
Provides synchronizer phase adjustment in full line increments
4
Manual
†
Auto
Freeze Recognition
Selecting Auto stores the last field in the frame synchronizer to
output if the input video is lost or corrupted.
5
Off
†
On
Freeze Manual
Enables/Disables manual selection of Freeze Mode according to
positions 6 and 7.
6
Frame
†
Field
Freeze Mode
Select between Frame and Field.
7
Field 1
†
Field 2
Freeze Field
Select between Field 1 and Field 2.
8
Last Field
†
Black
Freeze Signal
Selects the freeze output signal if Auto or manual freeze is acti-
vated.
9, A-F
currently not used