Grass Valley 2042EDA User Manual
Page 13
2042EDA Instruction Manual
7
Power Up
A red FAULT LED indicates an error situation and, when noted with
the other indicator LEDs, can indicate a specific problem area.
describes signal output and LED indications for the various input/ref-
erence combinations.
provides the possible input and output conditions that result
from different input signals and conditions.
Table 1. Indicator LEDs and Conditions Indicated
LED
Indication
Condition
Off Normal
operation
FAULT (red)
On continuously
Module has detected internal fault
Long flash
No input signal on input 1 or input 2
COMM (yellow)
Off
No activity on frame communication bus
Long flash
Location Command received by the module from a remote control system
Short flash
Activity present on the frame communication bus
CONF (yellow)
Off
Module is in normal operating mode
On continuously
Module is initializing, changing operating modes or updating firmware
PWR (green)
Off
No power to module or module’s DC/DC converter failed
On continuously
Normal operation, module is powered
SIG 1 PRES
(green)
Off
Indicates input 1 signal carrier missing or over EQ range
On
Indicates input 1 signal carrier present
SIG 2 PRES
(green)
Off
Indicates input 2 signal carrier missing or over EQ range
On
Indicates input 2 signal carrier present
SIG (rear view)
(green)
Off
Indicates both input 1 and 2 signal carriers missing
On continuously
Indicates both input 1 and 2 signal carriers present
Long Flash
Indicates input 1 missing, input 2 present
Short Flash
Indicates input 1 present, input 2 missing
Table 2. Input and Output Conditions
Input Condition
Output Condition
Serial Digital Component (SDI)
Serial Digital Component (SDI)
HD Digital Component (SDI)
HD Digital Component (SDI)
Other carrier (SMPTE 310M, DVB-ASI)
Other carrier (SMPTE 310M, DVB-ASI)
No input signal
Muted
Cable exceeding 200 – 300 meters
Muted