beautypg.com

Auto/bypass jumper – Grass Valley 2041RDA User Manual

Page 14

background image

14

2041RDA Instruction Manual

Configuration

Figure 5. Module Configuration Jumpers

Auto/Bypass Jumper

When the jumper is placed across pins 2 and 3 of jumper block J25, the
detected video signal will be reclocked at the appropriate rate. With the
jumper across pins 1 and 2, all reclocking is bypassed.

8025_06

JP24

JP25

FAULT

COMM

CONF

PWR

REMOVR

SIG_PRES

RECLOCK

Jumper across pins 2–3
selects automatic reclocking

Jumper across pins 1–2
bypasses reclocking function

AUTO

BYPASS

1

CONF –
configuration
processing LED

Auto/Bypass Reclocking

Jumper across pins 1–2 enables
remote and local control

Jumper across pins 2–3
locks out remote control

LOCAL

LOCAL & REM

1

Remote Control Lockout