Configuration, Local on-board module configuration, Remote control jumper – Grass Valley 2041RDA User Manual
Page 13

2041RDA Instruction Manual
13
Configuration
Configuration
The 2041RDA can be configured locally using on-board jumpers or
remotely using the 2000NET network interface.
The following parameter options can be set on the 2041RDA module:
•
Remote control and monitoring lockout (on-board only),
•
Automatic signal locking and reclocking mode,
•
Reclock/Bypass mode (enabled/disabled reclocking), and
•
Manual input signal selection mode (remote only).
Local On-board Module Configuration
The 2041RDA module can be configured locally using the jumpers shown
in
. The CONF LED indicates status of the configuration
process.
These components perform the following:
•
Jumper J24 – sets control mode for Local only or Remote and Local.
•
Jumper J25 – enables or disables the reclocking function.
•
CONF (configuring) LED – when on, indicates the module is initial-
izing or processing configuration information.
Remote Control Jumper
When the jumper is placed across pins 2 and 3 of jumper block J24, module
settings are changed from the on-board jumpers only. To have both Local
and Remote access, set the jumper across pins 1 and 2.